PROTECCIONES EN BAJA TENSIÓN spare parts, available from every manufacturer.
75,332 products found

3VX7625-3AA00 BARA BA?LANTI TAKIMI
New
87,13 €
3VX7725-3AA00 BARA BA?LANTI TAKIMI
New
87,13 €
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity S Icu=66/50kA at 500/690V, Trip unit ETU300 LSI optimized for standard applica- tions, without display Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, without Com & metering function Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, without 1st Shunt trip
New
5832,99 €
Accessory 3WA/3WL Base part for secondary disconnect terminals
New
45,50 €
Accessory 3WA/3WL Secondary disconnect terminals SIGUT compressions screw terminals
New
44,48 €
Accessory 3WA/3WL Closing coil (CC) / Shunt trip (ST), 100% OP 208-240 V AC / 220-250 V DC for continuous duty
New
145,64 €
Siemens 3WA9111-0AE06 D\\u00fc\\u015f\\u00fck Gerilim Bobini 208-240V Ac
Request price

Accessory 3WA/3WL Undervoltage release (UVR) Instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC,
New
215,42 €
Accessory 3WA/3WL Undervoltage release (UVR-t), with time delay 0,2-3,2 s 208-240 V AC / 220-250 V DC,
New
432,78 €
Accessory 3WA/3WL Charging Motor (M) 208-240 V AC / 220-250 V DC
New
777,71 €
Accessory Circuit breaker 3WA, Ready-to-close signaling switch S20
New
82,62 €
withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC
New
5722,11 €
fixed-mounted circuit breaker 3-pole, size I, IEC In=2000A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC
Request price

fixed-mounted circuit breaker 3-pole, size II, IEC In=1000A to 690V, AC50/60Hz Icu=100kA at 500V frnt.conn. top/bot. dual-hole
Request price

WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 3-POLE, SIZ
Request price

FIXED BUILT-IN CIRCUIT BREAKER 3-POLE, SIZE 2, IEC IN=1250A ...
Request price

WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 3-POLE, SIZ
Request price

WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE I
Request price

FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE 2, IEC IN=2500 A
Request price

withdrawable circuit breaker with guide frame 3-pole, size II, IEC In=3200A to 690V, AC50/60Hz Icu=80kA at 500V w. connection flange Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground
Request price

WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE I
Request price

fixed-mounted circuit breaker approved to UL489 3-pole, BG II, In=2000A AC 50/60 Hz, IEC: to 690V, 100kA at 440V ul: to 600V, 100kA at 480V rear connection horizontal
Request price

ACCESORIOS P/ INTERRUPTORES 3WL TRANS. INTENSIDAD INTER. T. I PARA PROTECCION DEL NEUTRO TRANSFORMADOR ROGOWSKI
Request price

ACCESORIOS P/ INTERRUPTORES 3WL TRANS. INTENSIDAD INTER. T. II PARA PROTECCION DEL NEUTRO TRANSFORMADOR ROGOWSKI
Request price